3520B VFD-S Inverter Configuration

PDF logoIf you would like your own hardcopy of this description, click here

Powermatic 3520B lathe
VFD-S Inverter
Delta VFD015S21U

Below is the configuration information for the Powermatic 3520B Lathe VFD-S Inverter as provided by Billy Burt. Feel free to grab a copy of the PDF containing this information.

  • Identity Code of AC Drive Read only
  • Rated Current Display Read only
  • Parameter Reset d0
  • Start-up Display Selection d0
  • User-Defined Unit d0
  • User-Defined Coefficient K d1.0
  • Software Version Read only
  • Password Input
  • Password Decode
  • Maximum Output Freq. d134.0
  • Maximum Voltage Frequency (Base Freq) d60.0
  • Maximum Output Voltage d230
  • Mid-Point Frequency d5.0
  • Mid-Point Voltage d20.0
  • Minimum Output Frequency d5.0
  • Minimum Output Voltage d20.0
  • Upper Bound of freq. d100
  • Lower Bound of freq d0
  • Acceleration Time 1 (Tacc1) d5.0
  • Deceleration Time 1 (Tdec1) d5.0
  • Acceleration Time 2 d10.0
  • Deceleration Time 2 d10.0
  • Jog Acceleration / Deceleration Time d10.0
  • Jog Frequency d6.0
  • Auto Acceleration / Deceleration d0
  • S-Curve in Acceleration d0
  • S-Curve in Deceleration d0
  • Jog Decelerating Time d0.0
  • Source of Frequency Command d01
  • Source of Operation Command d02
  • Stop Method d0
  • PWM Carrier Frequency d10
  • Reverse Operation d0
  • Loss of ACI Signal d0
  • Analog Auxiliary Frequency Operation d0
  • Analog Output Signal d0
  • Analog Output Gain d100
  • Desired Freq. Attained d1.0
  • Terminal Count Value d0
  • Preliminary Count Value d0
  • Multi-Function Output1 (Photocoupler Output) d1
  • Multi-Function Output2 (Relay Output) d8
  • Potentiometer Bias Frequency d0.0
  • Potentiometer Bias Polarity d0.0
  • Potentiometer Frequency Gain d100
  • Potentiometer Reverse Motion Enable d0.0
  • Multi-Function Input Terminal 1 (M0, M1) d01
  • Multi-Function Input Terminal 2 (M2) d6
  • Multi-Function Input Terminal 3 (M3) d7
  • Multi-Function Input Terminal 4 (M4) d8
  • Multi-Function Input Terminal 5(M5) d9
  • Line Start Lockout d1
  • Up/down frequency command mode d3
  • Acceleration /Deceleration speed of constant up/down frequency d1
  • 1st Step Speed Freq. d0.0
  • 2nd Step Speed Freq. d0.0
  • 3rd Step Speed Freq. d0.0
  • 4th Step Speed Freq. d0.0
  • 5th Step Speed Freq. d0.0
  • 6th Step Speed Freq. d0.0
  • 7th Step Speed Freq. d0.0
  • PLC Mode d0
  • PLC Forward/ Reverse Motion d0
  • Time Duration Step 0 d0
  • Time Duration Step 1 d0
  • Time Duration Step 2 d0
  • Time Duration Step 3 d0
  • Time Duration Step 4 d0
  • Time Duration Step 5 d0
  • Time Duration Step 6 d0
  • Time Duration Step 7 d0
  • Over-Voltage Stall Prevention d00
  • Over-Voltage Prevention Level d390
  • Over-Current Stall Prevention Level d130
  • Over-Torque Detection Mode d0
  • Over-Torque Detection Level d150
  • Time setting for Over-torque Detection d0.1
  • Electronic Thermal Overload Relay Selection d2
  • Electronic Thermal Characteris d60
  • Motor Rated Current d120
  • Motor No-Load Current d50
  • Torque Compensation d01
  • Slip Compensation d0.0
  • DC Braking Voltage Level d0
  • DC Braking Time during Start-Up d0.0
  • DC Braking time during Stopping d0.0
  • Start-Point for DC Braking d0.0
  • Momentary Power Loss Operation Selection d0
  • Maximum Allowable Power Loss Time d2.0

  • B.B. Time for Speed Search d0.5
  • Maximum Speed Search Current Level d150
  • Skip Frequency 1 Upper Bound d0.0
  • Skip Frequency 1 Lower Bound d0.0
  • Skip Frequency 2 Upper Bound d0.0
  • Skip Frequency 2 Lower bound d0.0
  • Skip Frequency 3 Upper bound d0.0
  • Skip Frequency 3 Lower Bound d0.0
  • Auto Restart After Fault d0
  • VR Functio d2
  • Dynamic Braking Voltage d380
  • DC Braking Lower Bound Limit d0.0
  • Communication Addre d1
  • Transmission Spee d1
  • Transmission Fault Treatme d0
  • Modbus Communication Watchdog Timer d0
  • Communication Protocol d0
  • PID Feedback Terminal Selection d0
  • Feedback Signal Gain d100
  • Proportional Gain (P) d100
  • Integral Time (I) d100
  • Differential Time (D) d0
  • Integrationís Upper Bound Frequency d100
  • One-Time Delay d0
  • PID Frequency Output Command Limit d100
  • Detection Time of the Feedback Error d0.0
  • Feedback Signal Fault Treatment d0
  • Dwell (sleep) Frequency d0.0
  • Revival Frequency d0.0
  • Dwell (sleep) Period d0.0
  • PID User Defined d0.0